Knowledge Base

Adding the RS40 Occupancy Sensor to an IoT Central Dashboard
This article describes how to add your RS40 Occupancy Sensor to an IoT Central Dashboard. Prerequisites: You have installed the Cascade-500W gateway and configured your IoT Central Application. You have activated the RS-40 Occupancy Sensor. 1. Verify the RS40 is online First we will confirm your RS-40 is online and paired with the gateway. Make […]
Activating your RS40 Occupancy & Motion Sensor
This article describes how to activate your RS40 Occupancy Sensor. Prerequisites: Make sure you have installed the Cascade-500W gateway and configured your IoT Central Application. Activating the RS40 Occupancy Sensor To setup the RS40, first make sure it is nearby (within 50 feet) of the Cascade-500W. Pull the tab on the battery.  The sensor lens […]
Building an Analytics Report with the HOBO MX-100 Temperature Monitor
This article describes how to build a time-series report using IoT Central Analytics and the HOBO MX-100 Temperature Monitor. Prerequisites: You have installed the Cascade-500W gateway and configured your IoT Central Application. You have activated the HOBO MX-100 temperature monitor. You have verified the HOBO MX-100 is online and sending data. Create an Analytics Report […]
Creating Alerts with the HOBO MX-100 Temperature Monitor
This article describes how to create an email alert using the HOBO MX-100 Temp Monitor . Prerequisites: You have installed the Cascade-500W gateway and configured your IoT Central Application. You have activated the HOBO MX-100. You have verified the HOBO MX-100 is online. 1. Create an Alert From your IoT Central application, select Rules from the left […]
Adding the HOBO MX-100 Temperature Monitor to an IoT Central Dashboard
This article describes how to add your Hobo MX-100 Temp Sensor to an IoT Central Dashboard. Prerequisites: You have installed the Cascade-500W gateway and configured your IoT Central Application. You have activated the HOBO MX-100 temperature monitor. 1. Verify the MX-100 is online First we will confirm your MX-100 is online and sending data to […]
Activating your HOBO MX-100 Temp Monitor
This article describes how to activate your HOBO MX-100 temperature monitor. Prerequisites: Make sure you have installed the Cascade-500W gateway and configured your IoT Central Application. Activating the Device To activate the device, first make sure it is nearby (within 50 feet) of the Cascade-500W. Press the button on the HOBO temp device to initiate […]